Heat shrinkable tubing 2:1 - PVDF
Art.-No. 311-00739
| TK20 73-PVDF-CL
|
Details
- Semi-rigid heat shrinkable tubing made of PVDF
- Thin wall and tough
- For higher temperature applications
- Very good mechanical strength, abrasion resistance and chemical resistance
- Meets various industrial standards
- Self extinguishing, UL 224 VW1 listed
Request your individual offer now
Request quote
More products in this product group:
Application | Typical applications of this translucent tubing are where high-temperature performance is required. Also very suitable for applications that ask for visual inspection of covered components, or if a low friction surface is needed. TK20 is also used as oil stop for energy cables. This thin walled, translucent heat shrink tubing is often used for chemical applications. |
Behaviour At Low Temperature | not cracking |
Behaviour at Heat Shock | not cracking, not dripping, not fluid |
Behaviour at low Temperature test method | SAE-AS23053 |
Colour | Transparent (CL) |
Elongation At Heat Aging | 200% |
Heat Aging Test | 168h/250°C |
Heat Aging test method | ASTM D638 |
Heat Shock Test | 4h/300°C |
Key product features | high temperature resistant, chemical resistance |
Material | Polyvinylidene Fluoride (PVDF) |
PART DESCRIPTION | TK20 73-PVDF-CL |
Pack Cont. | 1.2m |
Package Content packed in | Lengths |
Printable | No |
Product Family | TK20 |
Product Group | Heat shrinkable tubing 2:1 - PVDF |
Shrink Ratio | 2:1 |
Type | TK20 73 |
Variant | Thin-Wall |
With inner glue (Yes/No) | No |
Dielectric Strength | 30kV/mm |
Dielectric Strength test method | SAE-AS23053 |
Elongation at break | ≥350% |
Elongation at break test method | ASTM D882 |
Flammability | UL 224 VW-1 |
Halogen-free | No |
Insulation Class | F (VDE 0530) |
Minimum Shrink Temperature | +170 °C |
Operating Temperature | -55 °C to +175 °C |
ROHS compliant | Yes |
Self extinguishing | Yes |
Specifications | ANSI/UL 224 |
Specifications | |
Tensile Strength | 40MPa |
Test Method Tensile Strength | ASTM D412 |
UL OCD link | Link |
UL Recognized (US and Canada) | Yes |
UL-File Number | E198023 |
Volume Resistance | 10¹⁵ Ω cm |
Volume Resistance test method | ASTM D876 |
Water Absorption | 0.2% |