21/11/2024

Heat Shrinkable Tubing with Adhesive Liner 3:1 on a Reel 24/8 black
Art.-No. 308-12400 | HIS-A-24/8-PO-X-BK Details

  • Adhesive lined heat shrink tubing
  • Inner wall melts when heated and is forced into gaps
  • Adhesive forms seal against moisture as tubing cools
  • Protects components
  • Available in black and transparent
  • 6 sizes for wide range of applications
Show more

Request your individual offer now

Application HIS-A forms a seal against moisture and protects against corrosion and mechanical abrasion.
Behaviour At Low Temperature not cracking
Behaviour at Heat Shock not cracking, not fluid, not dripping
Behaviour at low Temperature test method UL 224
Colour Black (BK)
Elongation At Heat Aging 200%
Heat Aging Test 168h/158°C
Heat Aging test method UL 224
Heat Shock Test 4h/250°C
Heat shock test test method UL 224
Material Polyolefin, cross-linked (PO-X)
Minimum Tensile Strength At Heat Aging 12MPa
PART DESCRIPTION HIS-A-24/8-PO-X-BK
Pack Cont. 3m
Package Content packed in pcs.
Printable No
Product Family HIS-A - with adhesive liner
Product Group Heat shrinkable tubing 3:1 on a reel
Short Description Heat Shrinkable Tubing with Adhesive Liner 3:1 on a Reel 24/8 black
Shrink Ratio 3:1
Type HIS-A-24/8
Variant Thin-Wall
With inner glue (Yes/No) Yes
Length (L) 3m
Longitudinal Change After Shrinkage -10% max.
Recov. ∅ d 8.0mm
Supplied ∅ D 24.0mm
Tube Shape Flat
Wall (WT) 2.35mm
Weight/Unit 0.355kg
Wire Size Range (mm²) 11.2-20.8mm²
Adhesive Hot melt adhesive
CSA Certified Yes
Dielectric Strength 24kV/mm
Dielectric Strength test method IEC 60243
ELV compliant Dir. Art. 4 (2) YES
Elongation at break 600
Elongation at break test method ASTM D2671
Flammability UL 224 VW-1
Halogen-free No
Hazardous Goods No
Insulation Class A (VDE 0530)
Minimum Shrink Temperature +100 °C
Operating Temperature -55 °C to +125 °C
ROHS compliant Yes
Self extinguishing Yes
Softening Point Adhesive +85 °C
Specifications ANSI/UL 224, C22.2 no. 198.1-06, csa-C22.1, csa-C22.2 No.198.1
Specifications
Tensile Strength 14MPa
Test Method Tensile Strength ASTM D2671
UL OCD link Link Link
UL Recognized (US and Canada) Yes
UL-File Number E143529
Volume Resistance 10¹⁴ Ω cm
Volume Resistance test method UL 224
Country of Origin CN
Customs Number 39173200
GTIN-13 / EAN 4031026218632
Packaging 1 - Height (m) 0.048m
Packaging 1 - Length (m) 0.164m
Packaging 1 - Qty 1
Packaging 1 - Type Carton
Packaging 1 - Volume (m³) 0.00127
Packaging 1 - Weight (kg) 0.516kg
Packaging 1 - Width (m) 0.161m
Packaging 3 - Height (m) 0.4m
Packaging 3 - Length (m) 0.56m
Packaging 3 - Qty 40
Packaging 3 - Type Carton
Packaging 3 - Volume (m³) 0.0829
Packaging 3 - Weight (kg) 21.14kg
Packaging 3 - Width (m) 0.37m
Packaging 4 - Height (m) 0.95m
Packaging 4 - Length (m) 1.2m
Packaging 4 - Qty 320
Packaging 4 - Type pallet
Packaging 4 - Volume (m³) 0.912
Packaging 4 - Weight (kg) 190.12kg
Packaging 4 - Width (m) 0.8m
Reel Length 3.0m
ETIM 7.0 Key EC000217
ETIM 8.0 Key EC000217
ETIM 9.0 Key EC000217
UNSPSC Key 39121723

Request your individual offer now